Welcome to Shenzhen Donglaier Intelligent Technology Co.,Ltd website

Shenzhen Donglaier Intelligent Technology Co.,LtdWeChat QR code

Sweeping attention Donglaier smart WeChat QR code
Enjoy more information

Close

Terminal block module, relay module, optocoupler isolation module, signal isolation module, communication isolation module, communication I/O extension module, EtherCAT bus, CAN OPEN bus, RTX bus, Profinet NET bus, CC-LINK bus

Industrial automation total solution providerFocus on quick connect modules, bus modules, automation engineering

support hotline:+86-0755-29369330

24-hour hotline:15914121345

产品搜索

News

Contact Us

    Shenzhen Donglaier Intelligent Technology Co.,LTD
    Add:3/F, Building 108A, 7th Industrial Zone, Mashantou Community, Matian Street, Guangming District, Shenzhen.
    Tel:+86-0755-29369330
    Fax:+86-0755-29468353

    Mobile phone: 15914121345 Mr.Tan  (technical support)

                            15972616919 Mr. Li (business support)

    Contact person: Mr.Tan
    Email:yfdtzc@163.com
    Website:www.suncio.com
    taobao:https://shop107967679.taobao.com/
Location:Home > News > Company news
12.5mm ultra-thin DC signal isolator product introduction
Time:2018-07-12    Hits:1001
12.5mm ultra-thin DC signal isolator product introduction
The LW Series Signal Isolator is an electrical connection between the industrial field instrument and the control room. It effectively solves the interference problem of the industrial automation control system through the reliable isolation between the input-output and the power supply to ensure the stable and reliable operation of the system. This series of products adopts the international leading PCB transformer isolation technology, combined with advanced and efficient digital circuits, to further improve the anti-interference of the detection and control loops based on greatly improving the isolation strength of the products. At the same time, the current, voltage, resistance, galvanic couple, frequency and other signals are converted and distributed to meet the requirements of industrial automation control systems to a greater extent.

The LW series isolation barrier transmits the current signal, thermal resistance, thermocouple signal and switching signal from the hazardous area to the safety zone from the hazardous area to achieve complete isolation between the input-output-power channels. The products are designed according to the national standard GB3836.1 2010 "Explosive environment Part 1: General requirements for equipment", GB3836.4 2010 "Explosive environment Part 4: Equipment protected by intrinsically safe "i"". The barrier is an intrinsically safe associated device that connects the industrial field instrument to the control room meter. In addition, it can convert and distribute signals such as current, voltage, resistance, and galvanic to meet the needs of various industrial automation control systems.

1, 12.5mm ultra-thin, load capacity 350Ω (factory default, can specify the load) perfectly fits various PLC / DCS. Isolation, power distribution can be universal, high precision ± 0.1% F.S., low temperature drift, automatic zero calibration.
2, the use of new PCB transformer technology, input terminal current limit, protection of field equipment safety, super anti-interference ability. The input-output-power terminals have a withstand voltage of up to 2500VAC.
   The thermal resistance and thermocouple input parameters are directly programmed by the USB adapter, and the input parameters are read. No external power supply is required, and the parameter range can be adjusted according to the needs of the site.
 
3, humanized shell design, the bottom design of the heat dissipation channel; the terminal uses 0.5 ~ 2.5 (mm2) cable, the slotted cylinder head M3 screw is tightened, the screw torque is below 0.8Nm, the wiring is fast and the terminal can be plugged in and out. Front-end power indicator, feedback status of the instrument at any time.
4. It adopts 35mm standard DIN rail card type installation, low power consumption, small heat generation of the instrument, and can be installed intensively.
Signal isolators, safety barriers and other products are designed and manufactured in strict accordance with the latest regulations of GB3836.1-2010 and GB3836.4-2010 and passed the EU CE certification, national intrinsic safety explosion certification and ISO9001 quality management system certification. The company strictly implements the quality management system, and the products adopt standardized import production lines and high-precision testing equipment for standardized production to ensure the reliability of product quality.
Copyright © 2024  Shenzhen Donglaier Intelligent Technology Co.,Ltd all rights reserved     Address:3/F, Building 108A, 7th Industrial Zone, Mashantou Community, Matian Street, Guangming District, Shenzhen.      Technical Support:Boryin Net  
Support hotline:
+86-0755-29369330
Online service:
Official Wechat:
Website: www.suncio.com